EasyManua.ls Logo

Ricoh D147 - Page 513

Ricoh D147
2375 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Call 441-498
SM 5-39 D146/D147/D148/D149/D150
Troubleshooting
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC493-00 D High voltage power source: DS development: output error
"HVP:DS:output error detection signal" is detected “0
(abnormal) for 10 times consecutively (for 200ms) during output
of the PWM signal used as an error detection target
§ Leak harness fault
§ Unit fault
§ High voltage power source fault
§ Turn the power off/on
§ Reset or replacement the harness of high voltage power
supply feed path
§ Reset or replace the unit
§ Replace the high voltage power source
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC497-00 C Machine temperature detection thermistor error
Temperature sensor output error: Below 0.56V (90 degrees or
more), or above 3.0V (below -18 degrees)
§ Connector disconnection or broken
§ Sensor defective
§ Check the sensor setting
§ Replace the imaging temperature sensor (thermistor)

Table of Contents