EasyManua.ls Logo

Ricoh D147 - Page 545

Ricoh D147
2375 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Call 501-584
SM 5-71 D146/D147/D148/D149/D150
Troubleshooting
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC548-00 A Fusing Rotation Detection
During heating, there is no input to the edge of the rotation
sensor (t7) ms.
§ Motor defective
§ Sensor defective
§ Sensor actuator/feeler modification/defective
§ Replace the motor
§ Replace the sensor
§ Replace the actuator/feeler
§ Replace the fusing unit
SC No. Level Error Name/Error Condition/Major Cause/Solution
549-01 D Shield Operation Error Detection
During HP detection operation, shield sensors 1 and 2 detect
"High" for (t30) seconds continuously.
549-02 D Shield Operation Error Detection
During shield basic operation, shield sensor 2 does not go "Low
> High" even if (t31) seconds elapsed from screen motor rotation
start.
549-03 D Shield Operation Error Detection
During shield basic operation, shield motor does not stop even if
(t32) seconds elapsed from rotation start.
549-04 D Shield Operation Error Detection
During HP detection operation, HP detection fails 3 times
consecutively.
§ Motor defective
§ Sensor defective
§ Sensor actuator/feeler modification/defective
§ Shield modification/defective

Table of Contents

Related product manuals