Service Call 501-584
SM 5-79 D146/D147/D148/D149/D150
Troubleshooting
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC569-00 D Depressurizing Error Detection
Retry operation fails 3 times consecutively.
§ Motor defective
§ Sensor defective
§ Filler modification, defective
§ Replace the motor
§ Replace the sensor
§ Replace the fusing unit
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC571-00 A Pressurized Edge Thermistor Disconnection
Below 0 degree C (or above 3F9) detected for (t12)
continuously.
Detection period: 100 ms, detection counts: 10 times or more.
§ Thermistor disconnection
§ Connector disconnected
§ Replace the thermistor
§ Reset the connector
§ Replace the connector
§ Replace the fusing unit