Service Call 620-689
D146/D147/D148/D149/D150 5-88 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC669-30 D EEPROM Device detection: Communication abort error
SC669-31 D EEPROM Device detection: Communication timeout error
SC669-32 D EEPROM Device detection: Operation stopped error
SC669-33 D EEPROM Device detection: Buffer full
SC669-34 D EEPROM Device detection: No error code
§ Electrical noise
§ EEPROM not connected fully
§ EEPROM not installed
§ EEPROM damaged
§ BCU damaged
§ Turn the power off/on
§ Reconnect the EEPROM
§ Replace the EEPROM
§ Replace the BCU
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC681- Toner Cartridge: ID Chip Communication Error
01 - 04 D Invalid Device ID
06 - 09 D Channel error
11 - 14 D Device Error
16 - 19 D Communication aborted (error during communication)
21 - 24 D Communication timeout
26 - 29 D Device stopped (logically stopped)
31 - 34 D Requested buffer full
36 - 39 D No error code
§ When abnormality occurs at cable connection
§ When error notification was received during communication
with the tag and operation is not resumed after 3 retries.