Service Call 620-689
D146/D147/D148/D149/D150 5-94 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC637-02 D
Tracking Information Notification Error (Management server
error)
Tracking information was lost.
Communication with tracking management server failed.
§ Network error
§ tracking management server error
§ Tracking SDK application error
Turn the main power off/on.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC650-01 B
Remote Service Modem Communication Error (Dialup
authentication failure)
§ An error related to communication (dialup connection,
modem board etc.) using the RC Gate Type M was detected
or an error that prevents RC Gate operation was detected at
power on.
§ Displayed only when an error is detected while RC Gate is
operating.
§ SC is not issued if an error occurs during RC Gate
installation (because it can be referenced using SP).
Dialup authentication failure
Check the following SPs.
§ SP5-816-156
§ SP5-816-157