Service Call 620-689
D146/D147/D148/D149/D150 5-100 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC672-10 D
Controller start up error
After the machine was powered on, communication between the
controller and the operation panel was not established.
§ Controller stalled
§ Board installed incorrectly
§ Controller board defective
§ Operation panel connector loose, broken, or defective
§ Controller late
§ Turn the main power off/on.
§ Check the connection of the controller board.
§ Replace the controller board.
§ Check the control panel harness.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC672-11 D
Controller start up error
After the machine was powered on, communication between the
controller and the operation panel was not established, or
communication with controller was interrupted after a normal
startup.
§ Controller stalled
§ Board installed incorrectly
§ Controller board defective
§ Operation panel connector loose, broken, or defective
§ Controller late
§ Turn the main power off/on.
§ Check the connection of the controller board.
§ Replace the controller board.
§ Check the control panel harness.