Service Call 700-792
SM 5-107 D146/D147/D148/D149/D150
SC No. Level Error Name/Error Condition/Major Cause/Solution
Motor defective or a harness short-circuit occurs in the
non-interlocking power supply system.
§ Replace the blown fuse or circuit board
§ Replace the short-circuited parts
SC702-05 D Protection Device Intercept Error 5 (1-pass ADF)
Motor defective in the paper feed motor, pullout motor,
intermediate motor, scanner motor or paper exit motor, or a
harness short-circuit occurs, and the protection device of the
interlocking power supply system intercepts.
Motor defective or a harness short-circuit occurs in the
interlocking power supply system.
§ Replace the blown fuse or circuit board
§ Replace the short-circuited parts
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC720 2K/3K Sheet finisher Error
SC720-03 B Protection Device Intercept Error 1 (2K/3K sheet finisher)
Protection device intercept error state (fuse break) is detected.
§ Short-circuit defective
§ Overload defective
§ Motor defective
§ Solenoid defective
§ Check the harness
§ Replace the controller
§ Replace the motor
§ Replace the solenoid
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC720 2K/3K Sheet finisher Error
SC720-10 B Entrance Transport Motor Error (2K/3K sheet finisher)