Service Call 816-899
D146/D147/D148/D149/D150 5-162 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC864-08 D
HDD data CRC error
During HDD operation, the HDD returned a CRC error.
Bad sectors were generated during operation.
(An error occurred in partition "g".)
§ Format the HDD.
§ Replace the HDD.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC864-09 D
HDD data CRC error
During HDD operation, the HDD returned a CRC error.
Bad sectors were generated during operation.
(An error occurred in partition "h".)
§ Format the HDD.
§ Replace the HDD.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC864-10 D
HDD data CRC error
During HDD operation, the HDD returned a CRC error.
Bad sectors were generated during operation.
(An error occurred in partition "i".)
§ Format the HDD.
§ Replace the HDD.