Service Call 816-899
SM 5-183 D146/D147/D148/D149/D150
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-02 D
Log Data Error 2
An error was detected in the handling of the log data at power
on or during machine operation.
Log encryption is enabled but encryption module is not installed.
§ Replace or set again the encryption module.
§ Disable the log encryption setting.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-03 D
Log Data Error 3
An error was detected in the handling of the log data at power
on or during machine operation.
Inconsistency of encryption key between NV-RAM and HDD.
§ Disable the log encryption setting.
§ Initialize LCS memory (SP5801-019).
§ Initialize the HDD (SP5-832-004).
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-04 D
Log Data Error 4
An error was detected in the handling of the log data at power
on or during machine operation.
§ Log encryption key is disabled but the log data file is
encrypted. (NVRAM data corruption)
§ Log encryption key is enabled but the log data file is not
encrypted. (NVRAM data corruption)
Initialize the HDD (SP5-832-004).