Service Call 900-998
D146/D147/D148/D149/D150 5-198 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC998-00 D
Application start error
§ No application was registered to system within a specified
time after the main power was turned on.
(No application starts/All applications have been terminated
abnormally)
§ Application started but cannot be drawn now for some
reason.
§ Software bug (mainly the application)
§ The optional RAM, DIMM, boards required by the
application program. Are not installed correctly.
§ Turn the main power off/on.
§ Check the optional RAM, DIMM, boards
§ Check the combination of programs
§ Replace the controller board.