Main SP Tables-1
System Maintenance Section 2-93 D146/D147/D148/D149/D150
SP Mode Tables
042
Shading Position Temp: A3: 4 ENG
[0 to 250 / D146:180, D147:180,
D148:200, D149:200, D150:200 /
1deg/step]
Do not change. No 4 position (small shade) Transitions temperature of A3
043
Shading Position Temp: A3: 5 ENG
[0 to 250 / D146:185, D147:185,
D148:205, D149:205, D150:205 /
1deg/step]
Do not change. No 5 position (small shade) Transitions temperature of A3
044
Shading Position Temp: A3: 6 ENG
[0 to 250 / D146:190, D147:190,
D148:210, D149:210, D150:210 /
1deg/step]
Do not change. No 6 position (small shade) Transitions temperature of A3
045
Shading Position Temp: A3: 7 ENG
[0 to 250 / D146:195, D147:195,
D148:215, D149:215, D150:215 /
1deg/step]
Do not change. No 7 position (small shade) Transitions temperature of A3
046
Shading Position Temp: A3: 8 ENG
[0 to 250 / D146:200, D147:200,
D148:220, D149:220, D150:220 /
1deg/step]
Do not change. No 8 position (small shade) Transitions temperature of A3
047
Shading Position Temp: DLT:
4
ENG
[0 to 250 / D146:180, D147:180,
D148:160, D149:160, D150:160 /
1deg/step]
Do not change. No 4 position (small shade) Transitions temperature of DLT
048
Shading Position Temp: DLT:
5
ENG
[0 to 250 / D146:185, D147:185,
D148:170, D149:170, D150:170 /
1deg/step]
Do not change. No 5 position (small shade) Transitions temperature of DLT
049
Shading Position Temp: DLT:
6
ENG
[0 to 250 / D146:190, D147:190,
D148:180, D149:180, D150:180 /
1deg/step]

Table of Contents