Main SP Tables-2-1
D146/D147/D148/D149/D150 2-148 System Maintenance Section
0: Set to correction value using table.
1: Set to Fixed Value: Electrify DC Voltage of SP.
043 DC Bias Fixed Value Set *ENG [0 or 1 / 0 / 1/step]
2005
[Charge DC Voltage: Correction]
Fixed value of Vc calculating coefficient for DC Electrify.
044
Correction Coefficient a: Fixed
K
*ENG
[0.000 to 2.000 / 1.000 / 0.001/step]
045
Correction Coefficient a: Fixed
C
*ENG
046
Correction Coefficient a: Fixed
M
*ENG
047
Correction Coefficient a: Fixed
Y
*ENG
048
Correction Coefficient b: Fixed
K
*ENG [0 to 2000 / 0 / 1/step]
049
Correction Coefficient b: Fixed
C
*ENG
[0 to 2000 / D146: 20, D147: 20,
D148: 0, D149: 0, D150: 0 / 1/step]
050
Correction Coefficient b: Fixed
M
*ENG
051
Correction Coefficient b: Fixed
Y
*ENG
052
Correction Coefficient c: Fixed
K
*ENG [0 to 100 / 0 / 1/step]
053
Correction Coefficient c: Fixed
C
*ENG
[0 to 100 / D146: 10, D147: 10,
D148: 0, D149: 0, D150: 0 / 1/step]
054
Correction Coefficient c: Fixed
M
*ENG
055
Correction Coefficient c: Fixed
Y
*ENG