Main SP Tables-2-1
System Maintenance Section 2-201 D146/D147/D148/D149/D150
SP Mode Tables
2302 [Environmental Correction:Trans]
001
Current Environmental
Display
ENG [0 to 0 / 0 / 0/step]
Displays current environment division of transfer.
002
Forced Setting *ENG
[0 to 6 / 0 / 1/step]
0: Sensor detect
1: LL
2: ML
3: MM
4: HM
5: HH
6: SLL
Force sets current environment division of transfer.
003
Absolute Humidity:Threshold
1
*ENG
[0.00 to 100.00 / 4.00 /
0.01g/m3/step]
Sets environment division threshold (LL/ML)
004
Absolute Humidity:Threshold
2
*ENG
[0.00 to 100.00 / 8.00 /
0.01g/m3/step]
Sets environment division threshold (ML/MM)
005
Absolute Humidity:Threshold
3
*ENG
[0.00 to 100.00 / 16.00 /
0.01g/m3/step]
Sets environment division threshold (MM/HM)
006
Absolute Humidity:Threshold
4
*ENG
[0.00 to 100.00 / 24.00 /
0.01g/m3/step]
Sets environment division threshold (HM/HH)
007
Temperature:Threshold *ENG [-5 to 30 / 5 / 1deg/step]
Sets absolute temperature threshold (SLL)