EasyManua.ls Logo

Rockwell Automation Allen-Bradley Kinetix 5700 - Page 197

Rockwell Automation Allen-Bradley Kinetix 5700
234 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rockwell Automation Publication KNX-SG001H-EN-P - December 2020 197
Kinetix 6000 Multi-axis Servo Drives
Performance Specifications (frame 50) with Kinetix 6000 (400V-class) Drives
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient temperature and rated line
voltage. For additional information on ambient temperature and line conditions, refer to Motion Analyzer.
Linear Thruster
Cat. No.
Velocity, max
460V AC
m/s
System Continuous
Stall Current
A 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
A 0-pk
System Peak
Stall Force
N (lb)
Rated Output 460V
AC
kW
Kinetix 6000
400V-class Drives
LDAT-S051010-DBx 2.8
3.1 119 (27) 11.4 363 (82)
0.34
2094-BMP5-S
@ 150%
LDAT-S051020-DBx 3.7 0.43
LDAT-S051030-DBx 4.1 0.49
LDAT-S051040-DBx 4.4 0.53
LDAT-S051050-DBx 4.7 0.55
LDAT-S052010-DBx 3.7
6.2
251 (56)
22.7
727 (163)
0.92
2094-BM01-S
@ 150%
LDAT-S052020-DBx 4.8 1.20
LDAT-S052030-DBx
5.0 1.24LDAT-S052040-DBx
LDAT-S052050-DBx
LDAT-S052010-EBx 3.7
3.1 11.4
0.80
2094-BMP5-S
@ 150%
LDAT-S052020-EBx 4.6 0.98
LDAT-S052030-EBx
4.6 1.02LDAT-S052040-EBx
LDAT-S052050-EBx
LDAT-S053010-DBx 4.1
9.4
378 (85)
34.2
1093 (246)
1.56
2094-BM02-S
@ 150%
LDAT-S053020-DBx
5.0 1.87
LDAT-S053030-DBx
…
LDAT-S053050-DBx
LDAT-S053010-EBx
…
LDAT-S053050-EBx
3.5 3.1 11.4 1.04
2094-BMP5-S
@ 150%
LDAT-S054010-DBx 4.4
12.4
509 (114)
45.5
1453 (327)
2.26
2094-BM02-S
@ 150%
LDAT-S054020-DBx
…
LDAT-S054050-DBx
5.0 2.53
LDAT-S054010-EBx 4.4
6.2 22.7
1.87
2094-BM01-S
@ 150%
LDAT-S054020-EBx
…
LDAT-S054050-EBx
5.0 2.05

Table of Contents

Other manuals for Rockwell Automation Allen-Bradley Kinetix 5700

Related product manuals