208 Rockwell Automation Publication KNX-SG001H-EN-P - December 2020
Kinetix 300 and Kinetix 350 EtherNet/IP Servo Drives
Kinetix 300 and Kinetix 350 Servo Drive Selection
Kinetix 300 and Kinetix 350 Drive Operation with 240V Input Voltage
For Kinetix 300 and Kinetix 350 drive module specifications not included in this publication, refer to the Kinetix Servo Drives Technical Data,
publication KNX-TD003
.
Kinetix 300 Drives
Cat. No.
Kinetix 350 Drives
Cat. No.
Input Voltage
Continuous Output Power
kW
Continuous Output Current
A 0-pk
Features
2097-V31PR0 2097-V31PR0-LM
120/240V AC rms, single-phase
(1)
(1) Expect the same motor performance with 240V single-phase input as you can get from the 240V three-phase input (refer to the table below).
0.40 2.8
•120V Doubler mode
• Safe Torque-off
2097-V31PR2 2097-V31PR2-LM 0.80 5.7
2097-V32PR0 2097-V32PR0-LM
240V AC rms, single-phase
(1)
0.40 2.8
• Integrated AC line filter
• Safe Torque-off
2097-V32PR2 2097-V32PR2-LM 0.80 5.7
2097-V32PR4 2097-V32PR4-LM 1.70 11.3
2097-V33PR1 2097-V33PR1-LM
120V AC rms, single-phase,
240V AC rms, single-phase
(1)
,
240V AC rms, three-phase
0.50 2.8
Safe Torque-off
2097-V33PR3 2097-V33PR3-LM 1.00 5.7
2097-V33PR5 2097-V33PR5-LM 2.00 11.3
2097-V33PR6 2097-V33PR6-LM 3.00 17.0
2097-V34PR3 2097-V34PR3-LM
480V AC rms, three-phase
1.00 2.8
2097-V34PR5 2097-V34PR5-LM 2.00 5.7
2097-V34PR6 2097-V34PR6-LM 3.00 8.5
Three-phase Operation
with 240V Input
Single-phase Operation with 240V Input
Continuous Output Current
A 0-pk
Peak Output Current
A 0-pk
2097-V33PR1-xx 2097-V32PR0-xx 2097-V31PR0-xx 2.8 8.5
2097-V33PR3-xx 2097-V32PR2-xx 2097-V31PR2-xx 5.7 17.0
2097-V33PR5-xx 2097-V32PR4-xx N/A 11.3 33.9