DISPLAY PANEL MANUAL
5-27
Setting the detail of the TIGHTEN
Following items are set up in the detail setting of the TIGHTEN. Help windows of each item are displayed on
the bottom of the screen.
For more details, refer to the USERS MANUAL.
Figure 5.3-11 DETAIL SETTING SCREEN OF TIGHTEN
Input the value using numeric input keys and press EXEC. Press QUIT to cancel all new settings.
The contents of the value inputted on this screen are written to the NUTRUNNER when EXEC is pressed on the
Figure 5.3-6 SELECT PROGRAM SETTING SCREEN.
ITEM CONTENTS NOTE
Fastening Method The target fastening method is set.
Speed[rpm] The target constant speed is set.
Acceleration
(Deceleration)
The acceleration (or deceleration)
rate used to reach
the set speed.
Range 11000
Recommended value
0002
Maximum
Speed[rpm]
The maximum speed for the PERIODICAL ANGLE
MONITORING TORQUE CONTROL is set. This item
appears when the Periodical Control is selected.
Only Periodical
Control
Not applicable in
other methods.
Table 5.3-5 SETTING ITEMS OF TIGHTEN SELECT PROGRAM SETTING