Item
Identifier
Category/Description
Valid range
g
”Mr:”
This is not used with this specification. This parameter is ignored.
Timeout/Number of retry (Default: 4)
Change the setting of timeout/number of retry in the module.
Specified
number
0
1
2
3
4
5
6
7
ThingMagic
(msec)
50
100
200
500
1000
1500
2000
4000
"0" to "7"
1 digit
(Necessary
to reboot
after
changing)
h
”Ed:”
Recovery at tag error
Set recovery method at tag error. (Default Value: 0)
0(30H) : RETRY mode
1(31H) : RELEASE mode
(0,1)
1 digit
i
”Es:”
Slash printing at tag error (default: 1)
0 (30H) : Disable
1 (31H) : Enable
(0,1)
1 digit
j
”Eo:”
Signal setting at tag error (default: 1)
0(30H) : PULSE
1(31H) : LEVEL
(0,1)
1 digit
k
”Pl:”
Pulse length
Setting of pulse length of external signals at RFID tag error. (Default Value: 1)
Specified
number
1
2
3
4
5
Msec
100
200
300
400
500
"1" to "5"
1 digit
l
”Pm:”
PREND TYPE 3/4 setting
Setting of external signal PREND type 3/4 (Default 0)
0 (30H): Normal
1 (31H): Reflect tag writing period to the signal
(0,1)
1 digit
m
”Iv:”
Inventory setting
Setting whether to check the captured label or not before writing data by EPC code
write command <IP0> and read data by tag data print command <TU>. The default
is "1: INVENTRY enabled."
When this setting is enabled, and the number of captured tag is more than 1,
"MULTI TAG ERROR" occurs to prevent writing to (or reading from) the neighbor
tag. When "MULTI TAG ERROR" occurs frequently, some measures need to be
taken such as lowering radio power setting.
Note that checking the number of captured tag by this INVENTRY setting is not
possible when the default value of each EPC area is the same to the neighbor tag.
Thus, this setting is valid only for products that EPC default value is unique code to
the neighbor tag.
0 (30H) : INVENTRY disabled
1 (30H) : INVENTRY enabled (default)
(0,1)
1 digit
(Necessary
to reboot
after
changing)
n
”It:”
INVENTRY timeout setting (Default value: 3)
Setting of timeout time for INVENTRY that is enabled with Iv: item.
Specified
number
0
1
2
3
4
5
6
7
ThingMagic
(msec)
25
50
75
100
150
200
300
500
"0" to "7"
1 digit
(Necessary
to reboot
after
changing)
o
”Rc:”
RFID Counter clear
Clear RFID counter RFID life counter is not cleared.
This specification is not recorded to the memory.
0 (31H) : Don't clear (Default when omitted)
1 (31H) : Clear
(0,1)
1 digit
p
”Rs:”
Restart after setting
Sets whether or not to the printer restarts after executing this command.
When this parameter is omitted, it becomes “Restart”.
This specification is not recorded to the memory.
0 (30H) : Don’t reboot (With 3 short beeps)
1 (31H) : Reboot (With 3 long beeps, default when omitted)
2 (32H) : Don’t reboot (Without beep)
Note: make sure to specify reboot when switching RFID enabled/disabled mode or
changing the setting of RFID module.
"0" to "2"
1 digit
q
”Ma:”
MCS serialization setting (Default value: 0)
0 (30H) : Disable
1 (31H) : Enable
(0,1)
1 digit