EasyManua.ls Logo

SATO s86ex - Page 321

SATO s86ex
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
313
Item
Identifier
Category/Description
Valid range
r
”Mb:”
Tag chip manufacturer setting (Default: 0)
0 (30H) : IMPNJ
1 (31H) : ALIEN
2 (32H) : NXP
"0" to "2"
1 digit
s
”Mc: ”
Pre-encoded tag setting (Default: 0)
0 (30H) : Disable
1 (31H) : Enable
(0,1)
1 digit
t
”Me:”
MCS prefix number of digits setting (Default: 0)
Set from 0 digit to 3 digits.
"0" to "3"
1 digit
u
”Mf:”
MCS prefix insertion setting (Default: 0)
0(30H) : AUTO
1(31H) : MANUAL
(0,1)
1 digit
v
”Mg:”
MCS prefix data setting (Default: 0)
0 (30H) : 0
1 (31H) : 01
2 (32H) : 10
3 (33H) : 11
|
7 (37H): 111
"0" to "7"
1 digit
w
”La:”
RFID log setting (Default: 0)
0 (30H) : Disable
1 (31H) : Enable
(0,1)
1 digit
x
”Lb:”
RFID log data setting (Default: 0)
0 (30H) : EPC and TID
1 (31H) : EPC
2 (32H) : TID
"0" to "2"
1 digit
1. The parameter that doesn't need to be changed can be omitted.
2. When omitted the item, the previous value will be maintained. (Excluding Rs:Rc: parameter)
3. When there is an error in a part of parameter, the other parameters specified together are disabled.
4. When changed the setting of parameter that is necessary to reboot after changing, make sure to specify rebooting.
[Coding Example]
<A>
<RA>2,Ec:03,Ce:0,Rs:0
<Z>
Explanation: the printer is configured to RFID enabled, the number of retries is 3, and do not print at command error.
The printer is not rebooted after execution of this command.
[Notes]
1. This command is valid only for the RFID option equipped printer.
2. This command cannot use together with other than <A><Z> command.
3. There are 3 long beeps and the printer is rebooted automatically when this command is sent to the printer.
When rebooting is not necessary, specify the parameter "Rs:0". There are 3 short beeps when the printer is not rebooted.
Specify "Rs:2" when rebooting and buzzer sound is not necessary.
4. Be sure to feed one label for adjusting the position after rebooting.
5. When changed the setting of parameter that is necessary to reboot after changing, make sure to specify rebooting.
6. The setting values of the menus listed below are changed accordingly by changing the value with this command.
Extended parameters that values are changed accordingly and menu screens
Item
Identifier
Screens changed accordingly
Menu
a
-
RFID module setting screen
RFID Mode
b
”Ec:”
MAX. ERR COUNT setting screen
RFID User Mode
ddd
”To:”
RFID_TAG OFFSET setting screen
RFID User Mode
eee
”Pw:”
ANTENNA POWER setting screen
RFID User Mode
fff
”Pr:”
ANTENNA POWER setting screen
RFID User Mode
h
”Ed:”
RFID RETRY MODE setting screen
RFID User Mode
i
”Es:”
RFID ERR SLASH setting screen
RFID User Mode
j
”Eo:”
RFID ERR OUTPUT setting screen
RFID User Mode
k
”Pl:”
LENGTH OF PULSE setting screen
RFID User Mode
l
”Pm:”
PREND TYPE 3/4 setting screen
Service Mode
m
”Iv:”
INVENTRY setting screen ENABLE/DISABLE
RFID Mode
n
”It:”
INVENTRY setting screen TIMEOUT
RFID Mode
q
”Ma:”
MCS setting screen
RFID User Mode
r
”Mb:”
MCS setting screen
RFID User Mode
s
”Mc:”
MCS setting screen
RFID User Mode
t
”Me:”
MCS setting screen
RFID User Mode
u
”Mf:”
MCS setting screen
RFID User Mode
v
”Mg:”
MCS setting screen
RFID User Mode
w
”La:”
Log setting screen
RFID User Mode
x
”Lb:”
Log setting screen
RFID User Mode

Table of Contents