Installing cable fittings
Page 128 OmniTrax Product Guide
3. For SC1 cable, split the two internal coaxial cables by carefully cutting the web between them.
4. For SC1 cables, make the offset cuts as follows:
• for cable-to-cable connections or terminators - the longer cable should be 25 cm
(10 in.) long; shorten the remaining cable by 15 cm (6 in.) from the end of the cable
• for zone bypass or cable splice applications - the longer cable should be 17 cm (6.7 in.)
long; shorten the remaining cable by 6 cm (2.5 in.) from the end of the cable
Figure 99: Stripping the gray outer jacket
Figure 100: Separate the coax cables - SC1
Note If an SC1 cable will be connected to another SC1 cable, the ridged
sides of the two cables must be offset and lined up (see Figure 101:
).
pry up the gray jacket at the
score lines, then peel back
the gray jacket with pliers.
score 80% into the outer
gray jacket DO NOT allow
the knife to contact the
coaxial cables inside.
SC1 sensor cable cross section
SC2 sensor cable cross section
80% penetration
carefully split the two coaxial cables