System Description
3-28
20077/021 US XTRA Operator’s Manual
04264 Procedure Set BX/225 XTRA Procedure Set with 225 ml bowl and BOTTOM
outlet reservoir
04278 Procedure Set BX/225 -
120µm
X
TRA Procedure Set with 225 ml bowl and BOTTOM
outlet reservoir - 120 μm
Catalogue No. Product Designation Contents Product Description
04258 X
RES T Blood Collection
Reservoir
XTRA Blood Collection Reservoir
with 40 µm filter and TOP Outlet
Hard shell container equipped with an integrated
filter to collect blood recovered from the field,
removing aggregates larger than 40 µm
diameter. In the TOP outlet version, the outlet
port is located on the lid of the device.
04275 X
RES B Blood Collection
Reservoir - 120µm
XTRA Blood Collection Reservoir
with 120 μm filter and BOTTOM
Outlet
Hard shell container equipped with an integrated
filter to collect blood recovered from the field,
removing aggregates larger than 120 μm
diameter. In the BOTTOM outlet version, the
outlet port is located on the bottom of the
device.
04259 X
RES B Blood Collection
Reservoir
XTRA Blood Collection Reservoir
with 40 µm filter and BOTTOM
Outlet
Hard shell container equipped with an integrated
filter to collect blood recovered from the field,
removing aggregates larger than 40 µm
diameter. In the BOTTOM outlet version, the
outlet port is located on the bottom of the
device.
04260 Collection Set TX X
TRA Collection Set with TOP outlet
reservoir and without Cardio Kit
Blood Collection Reservoir TOP packed together
with the accessory lines required to recover
blood from the operating field.
The aspiration line allows transference of the blood
aspirated from the operating field to the
reservoir while simultaneously coagulating it.
The vacuum line allows the reservoir to be
connected to the vacuum source.
04265 Collection Set BX X
TRA Collection Set with BOTTOM
outlet reservoir and without
cardio kit
Blood Collection Reservoir BOTTOM packed
together with the accessory lines required to
recover blood from the operating field.
The aspiration line allows transference of the blood
aspirated from the operating field to the
reservoir while simultaneously coagulating it.
The vacuum line allows the reservoir to be
connected to the vacuum source.
04276 Collection Set BX -
120µm
X
TRA Collection Set with BOTTOM
outlet reservoir - 120 μm filter
and without Cardio Kit
Blood Collection Reservoir BOTTOM with 120 µm
filter packed together with the accessory lines
required to recover blood from the operating
field.
The aspiration line allows transference of the blood
aspirated from the operating field to the
reservoir while simultaneously coagulating it.
The vacuum line allows the reservoir to be
connected to the vacuum source.
04266 Collection Set TX
Cardio
X
TRA Collection Set with TOP outlet
reservoir and Cardio Kit
Same as the Collection Set TOP, plus an additional
accessory kit for connection to an oxygenator or
circuit for ECC (Cardio Kit)
The Cardio Kit contains:
•Y Adapter
•1/4” Adapter Tubing
• Oxygenator Extension Line
• Luer-Lock Adapter
Table 3-4
Catalogue No. Product Designation Product Description
Table 3-3