RESETTING COMPONENTS
If instructed to do so by Spectra Logic Technical Support or by error
messages, you can reset certain library components as described in this
section. See Resetting the Library on page 358 if you need to reset the entire
library.
Reset the LCM
To reset the LCM, insert the tip of a toothpick or other similar non-
conductive object into the hole on the back of the LCM to press the reset
button.
Do not reset a component unless you are specifically instructed to do so. Trace data
generated by the library or the component may be lost when you perform a reset,
making diagnosing problems difficult.
Do not use a metallic object to press the reset button. You may inadvertently cause
an electrical short inside the module.
Resetting the LCM resets the motion control for the robotics. Any move requests fail
until the LCM completes its initialization.
Resetting the LCM resets the front panel and the web server. Any connections to
the library through the BlueScale web interface are lost. Wait five minutes for the
reset to complete and then reconnect. Backup operations are not affected.
Figure 212 The reset button on the Spectra PC.