EasyManua.ls Logo

Spectra T200 - Prepare the Library for Drive Cleaning

Spectra T200
584 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 15 — Maintaining the Drives Cleaning a Drive
December 2019 User GuideSpectra T200, T380, and T680 Libraries
469
Determine the Cleaning Method
The method you use to clean the drive depends on the following factors:
If... Then...
Auto Drive Clean is
enabled and a cleaning
partition is associated with
the storage partition,
The library automatically cleans the drives, including any Global
Spares, as needed. See Chapter 6 – Configuring and Managing
Partitions, beginning on page 177 for information about configuring a
cleaning partition and associating it with one or more storage partitions.
You can also clean the drive manually using a cleaning cartridge in the
cleaning partition (see Cleaning Partition Present on page 470).
A cleaning partition is not
associated with the storage
partition; your software
package includes features
that allow for scheduled
drive cleanings,
Use your storage management software to perform regularly scheduled
drive cleanings. Refer to your storage management software user
manual or vendor for instructions on how to set up scheduled
automatic cleanings.
You may choose to leave a cleaning cartridge in each storage partition,
particularly if you can configure your storage management software to
perform regular automated cleanings.
Important: Make sure that the cleaning cartridge has a barcode label.
Your software must be able to identify the cleaning cartridge and use it
only for cleaning drives. Any attempts to use a cleaning cartridge for
data storage causes backup failures.
A cleaning partition is not
associated with the storage
partition and your
software package does not
have features that allow
for scheduled drive
cleanings,
Import a cleaning cartridge into the partition and clean the drive
manually as described in No Cleaning Partition Present on page 471.
You may choose to leave a cleaning cartridge in each storage partition
so that it is available whenever you need it.
Important: Make sure that the cleaning cartridge has a barcode label.
Your software must be able to identify the cleaning cartridge and use it
only for cleaning drives. Any attempts to use a cleaning cartridge for
data storage causes backup failures.
A Global Spare drive
requires cleaning and a
cleaning partition is not
present,
Prepare and clean the drive as follows:
1. Pause the PostScan operation if it is using the Global Spare drive that
needs cleaning (see Pause the PostScan Process on page 297).
2. Temporarily substitute the Global Spare drive for a drive in a
partition that is associated with the Global Spare drive (see Use the
Global Spare Drive on page 403).
3. Clean the drive manually (see No Cleaning Partition Present on
page 471).
4. Reclaim the Global Spare drive so that it is again available for use as a
spare (see Undo the Global Spare Drive on page 406).

Table of Contents

Other manuals for Spectra T200

Related product manuals