Chapter 14 — Maintaining the Library Replacing the Air Filter
December 2019 User GuideSpectra T200, T380, and T680 Libraries
459
REPLACING THE AIR FILTER
A set of fans mounted in the lower front of the library pull cool air into the
library and circulate it to maintain the temperature within an acceptable
range. The air filter ensures that the air pulled into the library is free of
contaminants. A clogged air filter can cause operational problems due to
excessive temperatures inside the library.
You should inspect the filter at least once every three months as part of
your preventive maintenance procedures. If a filter appears to be clogged,
continue with the steps in this section.
Spectra Logic recommends keeping one or more new air filters on site to
use for replacement as often as is necessary. To purchase replacement air
filters, contact your sales representative (see Contacting Spectra Logic on
page 7).
Before You Begin...
Confirm that the Filter Needs To Be Replaced Because dust primarily
collects at the bottom of the air filter, it can be rotated 180°, top to bottom,
one time before it needs to be replaced.
Gather the Following Tools and Supplies Gather these supplies before
beginning the procedure.
A new filter from Spectra Logic
A flat blade screwdriver
Continue Library Operations While Replacing the Filter It is safe to
continue normal library operations, such as backups, while rotating or
replacing the air filter.
Caution
Some environments may require more frequent filter inspection and replacement.
If an air filter gets clogged quickly, consider moving the library to a more dust-free
location or improve the environment where it is located.