Chapter 12 — Library Troubleshooting Accessing the Library Interior and Troubleshooting Blockages
December 2019 User Guide—Spectra T200, T380, and T680 Libraries
388
2. Using a #2 Phillips screwdriver, remove the two screws securing the
upper access panel to the right side of the library (see Figure 236 on
page 387).
Rotate the bottom of the access panel outward to disengage the tabs
from the top of chassis, then lift the access panel off the chassis and set
it aside.
3. Perform any necessary troubleshooting or maintenance procedures.
Install the Side Access Panel
Use the following steps to reinstall the access panels.
1. Slide the top edge of the upper access panel into the slots on either side
the chassis so that the locking tabs on each side of the panel engage top
edge of the chassis.
2. Align the screw holes on the top edge of the upper access panel (circled in
Figure 236 on page 387) with the screw holes in the chassis. Use a #2
Phillips screwdriver to install the screws securing the cover to the chassis.
Note: The upper access panel can be identified by the lip on its lower
edge. This lip fits under the top edge of the lower access panel.
3. Position the lower access panel with the notched edge down, aligning
the holes on the top edge of the panel (circled in Figure 236 on
page 387) with the corresponding holes in the chassis. Use a #2 Phillips
screwdriver to install the screws securing the cover to the chassis.