130 TimeHub 5500 User’s Guide 097-55501-01 Revision M – January 2009
Chapter 3 Installing the TimeHub 5500
Installing Expansion Shelves
1. Connect one end of cable 060-55505-01 to the Expansion Link 1 connector on
the rear panel of the Master shelf. The connectors are gender-coded to ensure
correct installation.
2. Connect the other end of this cable to the Expansion Link 1 IN connector on the
rear panel of the Expansion shelf.
3. Connect one end of the second 060-55505-01 cable to the Expansion Link 2
connector on the Master shelf.
4. Connect the other end of this cable to the Expansion Link 2 IN connector on the
Expansion shelf.
5. Install a gender changer 128-55505-01 to the Expansion Link 2 OUT connector
on the Expansion shelf.
6. Install the Termination Connectors on the Expansion Link 1 OUT and Expansion
Link 2 OUT connectors.
7. Tighten all connections.
Connecting Multiple Expansion Shelves
You make the connections on the rear panel of the Master and Expansion shelves,
as shown in Figure 3-24. You need two cables (060-55505-01) for each Expansion
shelf, one gender changer (128-55505-01), and two Termination Connectors
(090-55505-01), which are included with the Expansion shelf kit.
1. Connect one end of cable 060-55505-01 to the Expansion Link 1 connector on
the rear panel of the Master shelf. The connectors are gender-coded to ensure
correct installation.
2. Connect the other end of this cable to the Expansion Link 1 IN connector on the
rear panel of the first Expansion shelf.
3. Connect one end of a second cable 060-55505-01 to the Expansion Link 2
connector on the Master shelf.
4. Connect the other end of this cable to the Expansion Link 2 IN connector on the
first Expansion shelf.
5. Connect one end of a third cable 060-55505-01 to the Expansion Link 1 OUT
connector on the first Expansion shelf.
6. Connect the other end of this cable to the Expansion Link 1 IN connector on the
second Expansion shelf.
7. Connect one end of a fourth cable 060-55505-01 to the Expansion Link 2 OUT
connector on the first Expansion shelf.

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals