184 TimeHub 5500 User’s Guide 097-55501-01 Revision M – January 2009
Chapter 4 Testing and Configuring the TimeHub
Provisioning the Outputs
A successful response is:
SYMMBITS 04-10-11 10:35:54
M SV267 COMPLD
;
2. Check the INSRVC setting by issuing the following TL1 command:
RTRV-EQPT::S1-OUTC:SV268:::PARAMETER=INSRVC;
which produces the following response, showing that this card is in-service
(INSRVC = N indicates that it is not in-service):
SYMMBITS 04-10-11 10:35:54
M SV268 COMPLD
"S1-OUTC::INSRVC = Y"
;
3. If this port is connected to a DS1 Output Connector card, you may need to
provision the output framing. Issue the following TL1 command:
ED-EQPT::S1-OUTC-PG2:SV271:::OUTESF=Y;
where S1- indicates Expansion shelf 1
OUTC indicates output group C
PG2 indicates Program Group 2 (channels 21 – 40)
SV271 is the ctag
OUTESF = Y indicates ESF (N indicates D4/SF)
The response to the above command is:
SYMMBITS 04-10-11 10:43:40
M SV271 COMPLD
;
4. Check the framing setting by issuing the following command:
RTRV-EQPT::S1-OUTC-PG2:SV272:::parameter=OUTESF;
which produces the following response:
SYMMBITS 04-10-11 10:43:40
M SV272 COMPLD
"S1-OUTC-PG2::OUTESF = Y"
;
This response shows that the output framing is set to ESF.

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals