EasyManua.ls Logo

Telit Wireless Solutions WE866E4-P - Get MQTT Connect

Telit Wireless Solutions WE866E4-P
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WE866E4-P AT Commands Reference Guide
80572ST10887A Rev. 0.0 109 2018-02-16
PRELIMINAR
Y
Response
Table 228, page 109, describes the responses and remarks for MQTT Connect command.
Synchronous Response
Table 229, page 109, describes the synchronous responses and remarks for MQTT Connect
command.
9.4.2 Get MQTT Connect
This command is used to get the status of MQTT connection.
Command Syntax AT+NMQTTCONNECT?
Parameter Description
Time Out Optional
Value range:
0-180
Format: Integer
Default value: 75
It specifies the maximum time limit to
connect to the server.
SSL Optional
Value range: 0,1
Format: Integer
Default value: 0
It specifies the secured connection using
SSL where,
0- disables SSL connection and
1-enables SSLconnection
Certificates Optional
Value range:
0-256
Format: String
Default value:
N/A
It specifies the CA certificate file path if ssl
connection is required.
Table 227 MQTT Connect Parameters
Parameters Mandatory/Optional Value Description
Table 228 MQTT Connect Response
Responses Remarks
OK Success.
ERROR If parameter is not valid.
Table 229 MQTT Connect Synchronous Response
Responses Remarks
OK Success.
ERROR If parameter is not valid.