EasyManua.ls Logo

Telit Wireless Solutions WE866E4-P - Socket Connection

Telit Wireless Solutions WE866E4-P
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WE866E4-P AT Commands Reference Guide
80572ST10887A Rev. 0.0 85 2018-02-16
PRELIMINAR
Y
Table 159, page 85, describes the Socket Bind parameters.
Response
Table 160, page 85, describes the responses and remarks for Socket Close command.
Synchronous Response
Table 161, page 85, describes the synchronous responses and remarks for Socket Close
command.
9.2.4 Socket Connection
This command is used to connect to a server. Prior to issuing this command, user is required
to establish L2 and L3 connection.
Command Syntax AT+SCO=<CID>,<Server IP Address>,<Server Port Number>
Parameter Description
Table 162, page 86, describes the Socket Connection parameters.
Table 159 Socket Close Parameters
Parameters Mandatory/Optional Value Description
CID Mandatory
Value range:0-15
Format: Integer
Default value: 0
It specifies the value given by issuing
AT+SC or AT+SA command.
Table 160 Socket Close Response
Responses Remarks
OK Success.
ERROR If parameter is not valid.
Table 161 Socket Close Synchronous Response
Responses Remarks
OK Success.
ERROR If parameter is not valid.

Table of Contents