WE866E4-P AT Commands Reference Guide
80572ST10887A Rev. 0.0 86 2018-02-16
PRELIMINAR
Y
Response
Table 163, page 86, describes the responses and remarks for Socket Connection command.
Synchronous Response
Table 164, page 86, describes the synchronous responses and remarks for Socket
Connection command.
9.2.5 Socket Create
This command is used to create a socket and add CID. Prior to issuing this command, user
is required to establish L2 and L3 connection.
Command Syntax AT+SC=<Family>,<Type>,[<Protocol>]
Parameter Description
Table 162 Socket Connection Parameters
Parameters Mandatory/Optional Value Description
CID Mandatory
Value range:0-15
Format: Integer
Default value: 0
It specifies the value given by issuing
AT+SC command.
Server IP
address
Mandatory
Value range:7-40
Format: Integer
Default value:
0.0.0.0
It specifies the Server IP address that is to
be connected.
Server Port
Number
Mandatory
Value range:
0-65535
Format: Integer
Default value: 0
It specifies the server port number to
connect.
Table 163 Socket Connection Response
Responses Remarks
OK Success.
ERROR If parameter is not valid.
Table 164 Socket Connection Synchronous Response
Responses Remarks
OK Success.
ERROR If parameter is not valid.