Testing(continued)
SWITCHPOSITIONCLOSEDCIRCUITSOPENCIRCUITS
INCREASEENGINERPM
2+3and5+62+1and5+4
NEUTRAL
NONE
ALL
DECREASEENGINERPM
2+1and5+42+3and5+6
6.Replacetheswitchiftestingdeterminesthatitisfaulty.
7.Iftheswitchtestscorrectlyandacircuitproblemstillexists,checkthewire
harnesses(seeAppendixA(pageA–1)).
8.Aftertestingiscomplete,connectmachinewireharnessconnectortothe
switch.
9.Assembleconsolearm(seeConsoleArm(page7–35)).
10.Turnthebattery−disconnectswitchtotheONpositionbeforereturningthe
machinetoservice.
Groundsmaster
®
5900&5910
Page6–75
ElectricalSystem:ComponentTesting
16227SLRevB