BatteryCharging(continued)
CAUTION
Donotchargeafrozenbatterybecauseitcanexplodeandcause
injury.Letthebatterywarmto16ºC(60ºF)beforeconnectingto
acharger.
Chargethebatteryinawell−ventilatedplacetodissipategases
producedfromcharging.Thesegasesareexplosive;keepopen
ameandelectricalsparkawayfromthebattery.Donotsmoke.
Nauseamayresultifthegasesareinhaled.Unplugthechargerfrom
theelectricaloutletbeforeconnectingordisconnectingthecharger
leadsfromthebatteryposts.
4.Followingthebatterychargermanufacturer’sinstructions,connectthe
chargercablestothebattery.Makesureagoodconnectionismade.
5.Chargethebatteryfollowingthebatterychargermanufacturersinstructions.
6.Occasionallycheckthetemperatureofthebattery.Ifthetemperature
exceeds52ºC(125ºF)ortheelectrolyteisviolentlygassingorventing,the
chargingratemustbeloweredortemporarilystopped.
Groundsmaster
®
5900&5910
Page6–145
ElectricalSystem:ServiceandRepairs
16227SLRevB