Installation(Figure341)(continued)
6.Removecapsthatwereplacedonhosesandttingsduringtheremoval
process.Usinglabelsplacedduringremoval,properlysecurehosesto
compressor.
7.Connectcompressorelectricalconnectortomachinewireharness.
8.Haveacertiedairconditioningservicetechnicianevacuatetheair
conditioningsystemcompletely,properlyrechargethesystemwithR134a
refrigerantandthenleaktestthesystem.A/Csystemcapacityis3.43lb
ofR134arefrigerant.
9.Lowerandsecurehood.
OperatorCab:ServiceandRepairs
Page9–8
Groundsmaster
®
5900&5910
16227SLRevB