Printed in the Federal Republic of Germany TR-Electronic GmbH 2008, All Rights Reserved
06/06/2019 TR - EMO - BA - DGB - 0019 - 08 Page 157 of 252
The PKE range is used to identify parameters and the type of access:
Order identification: Control => encoTRive
response identification: encoTRive => Control
0 : no order
1 : Request parameter value
2 : Change parameter value (word)
3 : Change parameter value (double word)
4 : Request parameter description
5 : -
6 : Request parameter value (array)
7 : Change parameter value (array word)
8 : Change parameter value (array double word)
9 : Request number of array elements
0 : no response
1 : Transmit parameter value (word)
2 : Transmit parameter value (double word)
3 : Transmit parameter description
4 : Transmit parameter value (array word)
5 : Transmit parameter value (array double word)
6 : Transmit number of array elements
7 : Order cannot be executed
Table 3: Parameter identification (PKE)
If the value 7 is given as the response identification (“Order cannot be executed”),
then the PWE range is assigned an error number, which specifies the cause of the
fault. These are shown in the following table:
Parameter is not an array
Description element cannot be changed
Description data not available
Address range inadmissible
Number of values inconsistent
Table 4: PKW error numbers