Bit
Value
Significance
Description
0
1
Ready to switch on
Power supply switched on, electronics initialized. Main
contactor de-energized, if applicable, pulses inhibited.
0
Not ready to switch on
1
1
Ready for operation
Ready for operation. Voltage on converter.
0
Not ready for operation
2
1
Run enabled
Enable electronics and pulses
0
Run inhibited
3
1
Fault
Fault present. Drive in “Fault” state.
0
Fault free
4
1
No OFF 2
0
OFF 2
OFF 2 command present.
5
1
No OFF 3
0
OFF 3
OFF 3 command present.
6
1
Switch-on inhibit
0
No switch-on inhibit
7
1
Warning
Drive continues to run; Warning present and can be seen
from P953. No acknowledgement
0
No Warning
8
Specific to operating mode
9
1
Command required
The control system is requested to take over command
0
Local operation
Only local control possible
10
Specific to operating mode
11
Specific to operating mode
12
Specific to operating mode
13
Specific to operating mode
14-15
Not used
Table 8: Status word P968 (ZSW)