8.5.1.25 PNU 308, Temperature warning
An appropriate warning is output if the temperature of the electronics exceeds this defined parameter
value.
8.5.1.26 PNU 309, Standstill range
The standstill range defines the maximum permissible position range by allowing the drive to move at
standstill without signaling a warning.
Only available in some variants, see chapter 6.2.5
8.5.1.27 PNU 310, Monitoring time
The monitoring time defines the start of the standstill monitoring after a positioning.
Only available in some variants, see chapter 6.2.5
8.5.1.28 PNU 400, STW2
The command set selection parameter (P402) can also be written by means of control word 2.
According to ProfiDrive profile 3.0, this must be carried out within the standard telegram 7.
8.5.1.29 PNU 401, ZSW2
The current command set parameter (P403) can also be read by means of control word 2. According
to ProfiDrive profile 3.0, this must be carried out within the standard telegram 7.
8.5.1.30 PNU 402, Command set selection
This parameter can be used to preselect a command set from the command set table. This will occur
the next time a positioning movement is started.