13 Configuration example with TIA
®
Portal
This chapter describes the configuration of encoTRive with PROFINET with the
current GSDML file. The configuration is exemplified using the TIA Portal V14
update 1 with a SIMATIC CPU1511-1 PN.
13.1 Installation of the GSDML file
First of all the encoTRive GSDML file must be installed. The current file can be
downloaded from the following website:
www.tr-electronic.de
The file is called “GSDML-V2.X-TR-encoTRive-yyyymmdd.xml”, whereby the following
coding is valid:
yyyy: Year
mm: Month
dd: Day
Now proceed as follows:
Start TIA Portal and in the Options menu item select Manage general
station description files (GSD)
Now select the folder directory containing the downloaded GSDML file about the
Source path
Activate the GSDML file in the checkbox and confirm the installation process with
the Install button.
Figure 31: Installation of the GSDML file
The encoTRive can then be found in the catalog under the directory
Other field devices/Additional Ethernet
devices/PROFINETIO/Drives/TR-Electronic/TR Antriebe/…