8.5.1.45 PNU 807, Digital IN Function; MD-300
About this 4-byte parameter to the 4 digital inputs different functions can be assigned: E.g. activation
of the hardware limit switches. For each input one byte is reserved.
8.5.1.46 PNU 808, Digital OUT Function; MD-300
About this 4-byte parameter to the 4 digital outputs different functions can be assigned.
For each output one byte is reserved.
8.5.1.47 PNU 809, Debounce time E; MD-300
Takeover of the signal level when the defined debouncing time in ms is expired.