8.5 List of encoTRive parameters
The following is a list of all the encoTRive parameters arranged in parameter number order. Each
parameter is specified in the form
where
PNU Parameter number
1-899 => encoTRive specific parameter
900-999 => PROFIdrive profile parameters; these are parameters, which stand in
connection with communication via PROFINET.
Name Parameter designation
Attribute Information in the form:
Access/Flash memory/Factory setting/Password protected/PZD configuration
Access: rw – read/write: Parameter can be read and written,
ro – read only: Parameter is write-protected
Flash- memory: f Parameter is stored in Flash on a 0/1 transition of the
value of Parameter 971.
- Parameter is not stored in Flash
Factory setting: w Parameter is preset to the default value when the
factory settings are loaded
- (Parameter 970: 1/0 transition)
Value is not preset to the default value
Password protected: s Parameter can only be written after the password
has been enabled.
PZD configuration: p Parameter can be mapped in the PZD telegram
Data type Data type according to Table 25 page 195 for simple parameters.
For arrays: Array[NumberElements] Data type of the array elements
Default Value which is pre-set in the factory.
Min Minimum value, whereby in case of “**”internally a dynamic change occurs
(see chapter 8.5.1.3, 8.5.1.18, 8.5.1.19)
Max Maximum value, whereby in case of “**”internally a dynamic change occurs
(see chapter 8.5.1.3, 8.5.1.18 and 8.5.1.19)