8.5.1.39 PNU 515, Max_acceleration
PNU
Name
Attribute
Data type
Type
Default
Min
Max
515
Max_acceleration
rw/f/w/s
C4
MD-300 / MP-XXX
10000
0
2000000000
MA-XXX
3000
0
200000000
Maximum acceleration and deceleration in rpm /sec
Is not interpreted as C4 data type.
see chapter 6.4
8.5.1.40 PNU 520, Operating hours
PNU
Name
Attribute
Data type
Default
Min
Max
520
Operating hours
rw/-/-/s
UNSIGNED32
0
0
4294967295
Operating hours counter, incremented only when controller activated.
8.5.1.41 PNU 802, Parameter initialized
PNU
Name
Attribute
Data type
Default
Min
Max
802
Parameter initialized
ro/f/w
UNSIGNED16
-
0
1
Indicates whether a valid image of the encoTRive object directory is stored in Flash.
If the parameter contains the value 0xAB18, a valid encoTRive object directory is stored in Flash.
8.5.1.42 PNU 803, Digital_Input; MD-300
PNU
Name
Attribute
Data type
Default
Min
Max
803
Digital_Input
ro/-/-/p
UNSIGNED16
-
0
16
Shows the status of the digital inputs: Bits 0-3 = Digital inputs 0-3.
see chapter 9
8.5.1.43 PNU 804, Digital_Output; MD-300
PNU
Name
Attribute
Data type
Default
Min
Max
804
Digital_Output
rw/-/-/p
UNSIGNED16
0
0
16
The digital outputs bit 0-3 (Byte 0) can be controlled using bit coding by means of this parameter. The
mechanical brake can be lifted superordinately by means of bit 7=1 (Byte 1).
Example: 1000 0000 0000 1111
see chapter 9
8.5.1.44 PNU 805, Reference point set
PNU
Name
Attribute
Data type
Default
Min
Max
805
Reference point set
rw/-/w
UNSIGNED16
0
0
1
Indicates whether the drive has been referenced. Value 1: Drive referenced, Value 0: Drive not
referenced. After referencing the parameter value is set permanent to 1.
Option Load factory default setting / manual overwriting: default parameter value = 0.
see chapter 6.2.2