USTER®
HVI 900
Instruction Manual
Uster Technologies, Inc.
Chapter 14
Version 4.0 (1.99) Appendix - Page 14-35
<-- Small A sample too small for an accurate
reading was used to obtain length and
strength properties
.
<-- Small Sample
A sample too small for an accurate
reading was used to obtain length and
strength properties.
<-- Retest
The measured value is not within the lot
limits set in the Status Menu.
<-Timeout)
The computer timed-out while waiting.
Small Sample (len) For length data to be received
from the length device driver.
<-Timeout Small
The computer timed-out while waiting.
Sample (strn) For strength data to be received from the
strength device driver.
<-- Retest
The property has been measured as a
two-sided bale. A sample must be tested
twice when this occurs.
Air On
The signal to the motor controller to turn
the micronaire air on was ignored.
Air Off
The signal to the motor controller to turn
the micronaire air OFF was ignored.
Bad Color
The measured color readings were
outside of the valid range. The range is
Rd: 40.0 - 87.0 and +b: 4.0 - 18.0.
Bad Read on
The motor controller produced
Track Home
an error while attempting to read the
track home sensor.