16.2 List of Parameters
16.2.2 List of Parameters
16-15
16
Parameter Lists
Pn163
2
Anti-Resonance Damp-
ing Gain
0 to 300 1% 0 All
Immedi-
ately
Tuning
page
8-49
Pn164
2
Anti-Resonance Filter
Time Constant 1 Cor-
rection
-1,000 to
1,000
0.01 ms 0 All
Immedi-
ately
Tuning
page
8-49
Pn165
2
Anti-Resonance Filter
Time Constant 2 Cor-
rection
-1,000 to
1,000
0.01 ms 0 All
Immedi-
ately
Tuning
page
8-49
Pn166
2
Anti-Resonance Damp-
ing Gain 2
0 to 1,000 1% 0 All
Immedi-
ately
Tuning
page
8-52
Pn170
2
Tuning-less Function-
Related Selections
0000h to
2711h
1401h All
Setup
page
8-11
Pn181
2
Mode Switching Level
for Speed Reference
0 to 10,000 1 mm/s 0 Linear
Immedi-
ately
Tuning
page
8-85
Pn182
2
Mode Switching Level
for Acceleration
0 to 30,000
1 mm/s
2
0 Linear
Immedi-
ately
Tuning
page
8-85
Pn205
2
Multiturn Limit 0 to 65,535 1 rev
65535
*2
Rotary
After
restart
Setup
page
6-25
Pn207
2
Reserved parameter
(Do not change.)
––
0010h
*1
All
––
Pn20A
4
Number of External
Encoder Scale Pitches
4 to
1,048,576
1 scale
pitch/
revolu-
tion
32768 Rotary
After
restart
Setup
page
10-6
Pn20E
4
Electronic Gear Ratio
(Numerator)
1 to
1,073,741,824
164 All
After
restart
Setup
page
5-42
Pn210
4
Electronic Gear Ratio
(Denominator)
1 to
1,073,741,824
11 All
After
restart
Setup
page
5-42
Pn212
4
Number of Encoder
Output Pulses
16 to
1,073,741,824
1 P/Rev 2048 Rotary
After
restart
Setup
page
6-20
Pn217
2
Average Movement
Time of Position Refer-
ence
0 to 10,000 0.1 ms 0 All
After the
change
and also
after the
motor has
stopped
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
Tuning-less Selection
When
Enabled
0 Disable tuning-less function.
After
restart
1 Enable tuning-less function.
n.X Reserved parameter (Do not change.)
n.X
Rigidity Level
When
Enabled
0 to 7 Set the rigidity level.
Immedi-
ately
n.X
Tuning-less Load Level
When
Enabled
0 to 2 Set the load level for the tuning-less function.
Immedi-
ately

Table of Contents