xi
Variable Tables
System Variable Table (Tree View)
The following table lists details on the system variables provided by MPE720 version 6.
Variable Name Register Comments
OnCoil
SB000004 Always ON
Clock
- Calendar
DayOfWeek SW00019 Calendar:Day of week
HoursMinutes SW00017 Calendar:Hours Minutes
MonthDate SW00016 Calendar:Month Day
Second SW00018 Calendar:Seconds
Year SW00015 Calendar:Year
CPU
- Controller
Error - CPU Error Status
Exception SB000413 Exception Error
Failure SB000410 Important Failure
IOError SB000419 I/O Error
ProgramError SB000418 User Calculation Error
Info - CPU Information
MemorySizeAvailable SL00026 Available PRG Memory (BYTE)
MemorySizeTotal SL00028 All Module Memory (BYTE)
SoftwareVersion SW00020 System Program Software Number
Status - CPU Status
Alarm SB000402 ALARM (1=Warning,0=Normal)
BatteryAlarm SB000487 Battery Alarm (1=Alarm)
Error SB000403 ERROR (1=Unusual,0=Normal)
Ready SB000400
READY (1=Normal,0=Converse/Own
Diagnose Unusual)
Running SB000401 RUN (1=Driving,0=Driving Stop)
RunSwitch SB00040F
RUN switch status at power is on
(1=RUN,0=STOP)
Stopped SB00040E
Running Stop Require
(From EWS:1=STOP,0=RUN)
WriteEnable SB000407 WEN (Write:1=Possible,0=Impossible)
WritingToFlash SB000406 FLASH (1=FLASH Driving)
Switches - CPU Switch
Configure SB000482 CNFG (0=ON,1=OFF)
Initialize SB000483 INIT (0=ON,1=OFF)
Stop SB000485 STOP (0=ON,1=OFF)
ErrorHigh
- High-Speed Program Error
Code SW00085 High-Speed Program Error Code
Count SW00084 High-Speed Program Error Count
ProgramNumber SW00154 Error Program Number
ReferProgramNumber SW00155 Function Program Number
ReferStep SW00156 Function Program Step Number