7.2
Motion Command Details
7-29
Detecting the OT Signal during Approach Speed Movement
* 1. The SERVOPACK EXT1 signal.
* 2. The SERVOPACK P-OT signal.
* 3. The SERVOPACK N-OT signal.
The stopping method when the OT signal is detected depends on the setting of SERVO-
PACK parameters.
z
Setting Parameters
HOME signal
*1
NOT
*3
POT
*2
Start Zero Point
Phase-C pulse
Creep Speed
(OL40)
Positioning Speed
(OL10)
Home Offset
(OL42)
Approach Speed
(OL3E)
Approach Speed
(OL3E)
Parameter Name Setting
OW
3C
Home Return Type
14: HOME LS & C pulse method
OL
10
Speed Reference
Set the positioning speed to use after detecting the phase-C pulse. The sign
is ignored.
The travel direction depends on the sign of the Home Offset.
OL
3E
Approach Speed
Set the speed to use when starting a zero point return.
The travel direction will depend on the sign of the approach speed.
OL
40
Creep Speed
Set the speed to use after detecting the home signal and the travel direction
(sign).
OL
42
Home Offset
Set the travel distance from the point where a phase-C pulse is detected.
The travel direction will depend on the sign.