Appendix E  Motion Parameter Details
E.2  Setting Parameter List
A-41
OL2C
Latch Zone Upper 
Limit Setting
1 = 1 reference unit
Yes
OW2E
Position Loop Gain
1 = 0.1/s
Yes
OW2F
Speed Loop Gain
1 = 1 Hz
Yes
OW30
Speed Feedforward 
Amends
1 = 0.01% (percentage of distribution segment)
Yes
OW31
Speed
Compensation
1 = 0.01% (percentage of rated speed)
Yes Yes
OW32
Position Integration 
Time Constant
1 = 1 ms
Yes
OW33
−
Reserved
−−
OW34
Speed Integration 
Time Constant
1 = 0.01 ms
Yes
OW35
−
Reserved
−−
OL36
Straight Line Acceler-
ation/ Acceleration 
Time Constant
Unit is according to OW03, bits 4 to 7 (Speed Unit).
Yes Yes
OL38
Straight Line Decel-
eration/ Deceleration 
Time Constant
Unit is according to OW03, bits 4 to 7 (Speed Unit).
Yes Yes
OW3A
Filter Time Constant
1 = 0.1 ms
Yes Yes
OW3B
Bias Speed for 
Index
Deceleration/Accel-
eration Filter
Unit is according to OW03, bits 0 to 3 (Speed Unit).
Yes
OW3C
Zero Point Return 
Method
0: DEC1 + C (DEC 1 and C-Phase)
1: ZERO (Zero signal)
2: DEC1 + ZERO (DEC 1 and zero signal)
3: C (C-pulse)
Ye
s
4 to 
10
: Reserve
d
−−
11
:
 C Pulse
12: POT & C Pulse
13:  POT Only
14: HOME LS & C Pulse
15: HOME Only
Yes
16: NOT & C Pulse
17: NOT Only
18: INPUT & C Pulse
19: INPUT Only
Yes
OW3D
Width of Starting 
Point Position Output
1 = 1 reference unit
Yes Yes
OL3E
Approach Speed
Unit is according to OW03, bits 0 to 3 (Speed Unit).
Yes
OL40
Creep Rate
Unit is according to OW03, bits 0 to 3 (Speed Unit).
Yes
OL42
Zero Point Return 
Travel Distance
1 = 1 reference unit
Yes
OL44
STEP Travel
Distance
1 = 1 reference unit
Yes Yes
OL46
External Positioning 
Final Travel Distance
1 = 1 reference unit
Yes
OL48
Zero Point Position in 
Machine Coordinate 
System Offset
1 = 1 reference unit
Yes Yes
OL4A
Work Coordinate 
System Offset
1 = 1 reference unit
Yes Yes
OL4C
Number of 
POSMAX Turns
Presetting Data
1 = 1 reference unit
• Invalid for linear type.
Yes Yes
(cont’d)
Register No. Name Contents SVB SVR