Apps
71
Heater Control
IMPORTANT: Heater Control app is only applicable to freezer configurations.
The device heater ensures optimum performance in freezers. The heater benefits include:
Touch screen heater clears condensation on the display.
Port heater prevents condensation on contacts.
UPS Battery requires a heater to operate below freezing temperatures.
The user interface displays current temperatures.
Figure 47 Heater Control Screen
Temperatures
The Temperature tab displays the current temperature for the following:
Serial Ports
USB Ports
Battery
Keyboard
Touch Panel (Freeze configurations only)
Ambient.
Serial Port Heater
Use the Serial Ports Heater tab to enable and set the heater for the serial ports.
Enable Heater - Turns on or off the serial port heater. When on, the switch turn red.
Heater on threshold - Set the temperature at which the heater turns on (default - 5°C/41°F).
Heater off threshold - Set the temperature at which the heater turns off (default - 15°C/59°F).

Table of Contents