Apps
71
Heater Control
IMPORTANT: Heater Control app is only applicable to freezer configurations.
The device heater ensures optimum performance in freezers. The heater benefits include:
• Touch screen heater clears condensation on the display.
• Port heater prevents condensation on contacts.
• UPS Battery requires a heater to operate below freezing temperatures.
• The user interface displays current temperatures.
Figure 47 Heater Control Screen
Temperatures
The Temperature tab displays the current temperature for the following:
• Serial Ports
• USB Ports
• Battery
• Keyboard
• Touch Panel (Freeze configurations only)
• Ambient.
Serial Port Heater
Use the Serial Ports Heater tab to enable and set the heater for the serial ports.
• Enable Heater - Turns on or off the serial port heater. When on, the switch turn red.
• Heater on threshold - Set the temperature at which the heater turns on (default - 5°C/41°F).
• Heater off threshold - Set the temperature at which the heater turns off (default - 15°C/59°F).