Welcome announcements
It is possible to define up to 20 (Aastra 415/430) or 50 (Aastra 470) welcome an-
nouncements. A welcome announcement comprises one or more (up to 20) se-
quences. In each sequence the parameters of the following table are to be config-
ured in AMS under CM_5.4_Welcome announcements:
Tab. 313 Configuration per sequence of a welcome announcement
These configuration possibilities can be used to define complex welcome an-
nouncements. An example of a welcome announcement with 3 sequences is given
below. The welcome announcement ends after sequence 3, and music is played
until the time configured under Internal ringing duration in CM_2.3.3_Time settings
has elapsed. The connection is then cleared down.
Tab. 314 Example of a welcome announcement
It is also possible to define endless loops that consist of one or more sequences. Ex-
ample: If the figure 2 is entered as the next sequence at sequence 3, sequences 2
and 3 are repeated until the connection is cleared down.
Other settings in CM_5.4_Announcement service:
Each welcome announcement can be individually activated or deactivated using
the Status parameter. The Delay parameter can also be configured within a range of
0 to 100 seconds for each welcome announcement (default value: 10 s). This value
defines the amount of time before the unanswered call is answered by the an-
nouncement service. The Announcement service for internal users parameter is a pa-
rameter that applies throughout the system. It determines whether or not internal
Parameter Parameter value Remarks
File number <10...29> The file number is also included in the name of the wave
file.
Pause signal <Ring back tone / External audio
source / Internal audio source /
Do not disturb>
This determines what is to be played in the pauses
between the sequences.
Pause duration <0...30> seconds The default value is 15 seconds. If the pause duration is 0,
the sequence skips directly to the next.
Next sequence <1...20> If the entry is the same sequence, it is repeated endlessly. If
the entry is blank or if it points to a non-existent sequence,
the welcome announcement ends.
Sequence File number Pause signal Pause duration [s] Next sequence
110 Ring-back tone 15 2
211 External audio source 30 3
312 External audio source 30

Table of Contents

Other manuals for Aastra 400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aastra 400 Series and is the answer not in the manual?

Aastra 400 Series Specifications

General IconGeneral
BrandAastra
Model400 Series
CategoryServer
LanguageEnglish

Related product manuals