User's Manual 67. Configuration Parameters Reference
Version 6.8 1025 Mediant 500L MSBR
67.13 IP Media Parameters
The IP media parameters are described in the table below.
Table 67-72: IP Media Parameters
Parameter Description
Energy Detector Parameters
Enable Energy Detector
CLI: energy-detector-enable
[EnableEnergyDetector]
Enables the Energy Detector feature. This feature generates events
(notifications) when the signal received from the PSTN is higher or
lower than a user-defined threshold (defined by the
EnergyDetectorThreshold parameter).
[0] Disable (default)
[1] Enable
Energy Detector Quality
Factor
CLI: energy-detector-
sensitivity
[EnergyDetectorQualityFactor]
Defines the Energy Detector's sensitivity level.
The valid range is 0 to 10, where 0 is the lowest sensitivity and 10
the highest sensitivity. The default is 4.
Energy Detector Threshold
CLI: energy-detector-
threshold
[EnergyDetectorThreshold]
Defines the Energy Detector's threshold. A signal below or above this
threshold invokes an 'Above' or 'Below' event.
The threshold is calculated as follows:
Actual Threshold = -44 dBm + (EnergyDetectorThreshold * 6)
The valid value range is 0 to 7. The default is 3 (i.e., -26 dBm).