User's Manual 482 Document #: LTRT-10466
Mediant 500L MSBR
Table 29-10: Charge Codes Table Parameter Descriptions
Parameter Description
End Time
CLI: end-time-<1-4>
[ChargeCode_EndTime<1-4>]
Defines the end of the time period in a 24 hour format, hh. For
example, "04" denotes 4 A.M.
Notes:
The first time period always starts at midnight (00).
It is mandatory that the last time period of each rule end at
midnight (00). This prevents undefined time frames in a
day.
Pulse Interval
CLI: pulse-interval-<1-4>
[ChargeCode_PulseInterval<1-4>]
Defines the time interval between pulses (in tenths of a
second).
Pulses On Answer
CLI: pulses-on-answer-<1-4>
[ChargeCode_PulsesOnAnswer<1-
4>]
Defines the number of pulses sent on answer.
29.18 Configuring Voice Mail
The Voice Mail Settings page allows you to configure the voice mail parameters. For a
description of these parameters, see ''Configuration Parameters Reference'' on page 779.
Notes:
The Voice Mail Settings page is available only for FXO and CAS interfaces.
For more information on configuring voice mail, refer to the CPE Configuration
Guide for Voice Mail User's Manual.
To configure the Voice Mail parameters:
1. Open the Voice Mail Settings page (Configuration tab > VoIP menu > GW and IP to
IP > Advanced Applications > Voice Mail Settings).