User's Manual 57. Syslog and Debug Recordings
Version 6.8 741 Mediant 500L MSBR
57.5 Filtering Syslog Messages and Debug Recordings
The device can filter Syslog messages and debug recording (DR) packets, which are sent
to a Syslog server and packet capturing application (such as Wireshark), respectively.
Filtering can be useful to reduce CPU consumption and minimize negative impact on VoIP
performance.
You can configure up to 30 filtering rules, each based on a selected filtering criteria (e.g.,
an IP Group). Each filtering criteria can be configured with a range. For example, you can
filter Syslog messages for IP Groups 1 through 4. For each filter criteria, you can enable or
disable Syslog messages and debug recording.
Debug recording can also be filtered using various filtering criteria such as SIP signaling or
signaling and media.
The following procedure describes how to configure Logging Filter rules in the Web
interface. You can also configure Logging Filter rules using the table ini file parameter,
LoggingFilters or the CLI command configure system > logging > logging-filters.
To configure a logging filtering rule:
1. Open the Logging Filters Table page (Configuration tab > System menu > Logging
> Logging Filters Table).
2. Click Add; the following dialog box appears:
Figure 57-4: Logging Filters Table - Add Record Dialog Box
3. Configure a logging filter according to the parameters described in the table below.
4. Click Submit, and then save ("burn") your settings to flash memory.
Note: To configure the Syslog debug level, use the 'Debug Level' parameter (see
''Enabling Syslog'' on page 737).
Table 57-5: Logging Filters Table Parameter Descriptions
Parameter Description
Index
[LoggingFilters_Index]
Defines an index number for the new table record.
Note: Each table row must be configured with a unique index.
Filter Type
CLI: filter-type
[LoggingFilters_FilterType]
Defines the filter type criteria.
[1] Any (default)
[2] Trunk ID = Filters according to a specified Trunk ID
(applicable only to the Gateway application)