User's Manual 67. Configuration Parameters Reference
Version 6.8 985 Mediant 500L MSBR
Parameter Description
[PulseDialGenerationMakeTime]
Defines the duration of the Make connection (on-hook) for
FXO pulse dial generation.
The valid value range is 20 to 120 (in msec). The default is
40.
Note: For this parameter to take effect, a device reset is
required.
[PulseDialGenerationInterDigitTime]
Defines the inter-digit duration (time between consecutively
dialed digits) for FXO pulse dial generation.
The valid value range is 300 to 1500 (in msec). The default
is 700.
Note: For this parameter to take effect, a device reset is
required.
67.10.12 Trunk Groups and Routing Parameters
The routing parameters are described in the table below.
Table 67-66: Routing Parameters
Parameter Description
Trunk Group Table
Web: Trunk Group Table
EMS: SIP Endpoints > Phones
CLI: configure voip > gw hunt-or-trunk-
group TrunkGroup
[TrunkGroup]
This table parameter configures and activates the device's
endpoints/Trunk channels. This is done by defining
telephone numbers and assigning them to Trunk Groups.
The format of the ini file table parameter is as follows:
[TrunkGroup]
FORMAT TrunkGroup_Index =
TrunkGroup_TrunkGroupNum, TrunkGroup_FirstTrunkId,
TrunkGroup_FirstBChannel, TrunkGroup_LastBChannel,
TrunkGroup_FirstPhoneNumber, TrunkGroup_ProfileId,
TrunkGroup_LastTrunkId, TrunkGroup_Module;
[\TrunkGroup]
For a description of this table, seeConfiguring Trunk Group
on page 373.
Note: Trunk Group ID 1 is denoted as 0 in the table.